Ultrasonic Flowmeter

Ultrasonic Flowmeter

GENERMAL INFORMATION

Clamp-on ultrasonic flowmeters are non-invasive, “no-contact” devices that measure liquid flow by attaching transducers directly to the exterior of an existing pipe. It primarily operates on the transit-time difference principle. Two ultrasonic transducers are mounted on the pipe, sending sound pulses back and forth between each other. The system measures the time difference between the signal traveling with the flow (downstream) and against the flow (upstream); this difference is directly proportional to the fluid’s velocity, allowing for precise volumetric flow calculation. Because they require no pipe cutting, welding, or process shutdown, they are an ideal choice for system retrofitting, temporary flow audits, and measuring hazardous or corrosive liquids. They are widely applied across HVAC systems, water distribution, oil & gas operations, and chemical processing, where maintaining pipe integrity is critical.

BRIEF INTRODUCTION

This product is a clamp-on type ultrasonic flow meter that uses transfer time technology. Clamp-on type ultrasonic flow meter is easy to install and no need to cut off the pipe which saves you lots of trouble and cost. At the same time, this ultrasonic flow meter has our unique calculation software to ensure high accuracy and low-velocity response.
This ultrasonic flow meter is widely applied in the oil industry, water treatment, pure water, chemical, etc. The flow meter could add the RTD model and the temperature sensor become an energy meter to monitor energy use and help to save energy.

FEATURES

  • Versatility: It can quickly verify the flow readings of other meters and log system values over an extended period.
  • Portability: It is lightweight and easy to move, allowing for installation on different pipes.
  • Non-Invasive: The clamp-on transducers mean no tapping or cutting of the pipe is required, just clamp it outside the pipe.
  • Ease of Installation: It can be easily set up without complex procedures.
  • Suitable for Various Applications: It is excellent for measuring flows throughout plumbing infrastructure to verify the performance of sensors, pumps, and valves.
  • Data Logging Capability: It has the ability to log flow data, facilitating long-term monitoring and analysis.

MAIN SPECIFICATIONS (WALL-MOUNTED TYPE)

Flow range ±0.09ft/s ~ ±16ft/s (±0.03m/s ~ ±5m/s)
Accuracy ±1% of reading (for ±1.5ft/s ~ ±40ft/s)
Repeatability 0.2% of measured value
Linearity ±1%
Pipe size 1″ to 48″ (25mm to 1200mm). Pipe size under 1″ is available as an option
Outputs Analog output: 4~20mA, max load 750Ω

Pulse output: 0~10KHz

Communication RS232 / RS485 Modbus
Power supply 10~36VDC/1A
Display 240*128 backlit LCD
Operating Temperature Transmitter: -14°F ~ 140°F (-20°C ~ 60°C)
Transducer: -40°F ~ 176°F (-40°C ~ 80°C, standard)
Operating Humidity Up to 99% RH, non-condensing
Transmitter Housing PC/ABS material, IP65 protection rating
Transducer IP68 protection rating, encapsulated design
Double-shielded transducer cable
Standard/maximum cable length: 30ft/900ft (9m/274m)

MAIN SPECIFICATIONS (HAND-HELD TYPE)

Flow Range ±0.03ft/s ~ ±40ft/s (±0.01m/s ~ ±12m/s)
Accuracy ±1% of measured value
Pipe Size Clamp-on: 1/2″ ~ 48″ (15mm ~ 1200mm)
Measurable Fluid Single medium liquid
Compatible Pipe Material Carbon steel, stainless steel, PVC and other compact material pipes
Output Signals Analog output: 4~20mA, max load 750Ω
Modbus: RS485
SD Card Storage 32G
Data Logging Interval 1 ~ 99999 seconds
Input Method Digital keyboard
Display 240*128 backlit LCD
Power Supply Rechargeable 3000mAh lithium battery
Continuous operation of main battery: 16 hours
Operating Temperature Transmitter: -20℃ ~ 60℃

Transducer: -40℃ ~ 80℃ (standard); -40℃ ~ 130℃ (optional)

Operating Humidity Up to 99% RH, non-condensing
Transmitter Housing NEMA13, IP54 protection rating
Transducer IP68 protection rating, encapsulated design
Transducer Cable Standard cable length: 5m (16ft) for 1MHz; 3m (9ft) for 2MHz

MAIN SPECIFICATIONS (MINI TYPE)

Product Type Clamp On Type Ultrasonic Flow Meter
Compatible Pipe Range OD9.53 – OD110 (DN6 – DN100)
Measurable Medium Water, Chemical solvents etc. (solid inclusions content < 4%)
Maximum Medium Viscosity <300CST (mm²/s)
Flow Range 0.1 m/s ~ 5.0 m/s
Accuracy ±2.0% (at 0.3m/s ~ 5.0m/s)
Linearity ±2.0% (at 0.3m/s ~ 5.0m/s)
Repeatability 0.80%
Response Time 500ms
Display Screen 1.3″ 128*64 OLED display, 180° rotatable for easy reading
Display Digits 7-digit display
Language English
Display Units Metric and English units available: m³/h, LPM, GPM, LPH
Default unit: m³/h
Displayable Data Flow rate, Flow velocity, net totalizer, single totalizer, day/month/year totalizer
Data Storage Capacity 10 years, 64 months, 64 days of data storage
Keypad 4 touch keys
Calendar Battery CR1220
Power Supply 24VDC@3W
Analog Output 4-20mA, maximum load 600Ω
Communication Interface RS485, supports Modbus RTU protocol
Alarm Output OCT output, upper and lower limit alarm function (optional)
Relay Output 30VDC@1A, switching frequency < 2Hz (optional)
Standard Cable Length 2m (extendable up to 20m)
Protection Grade IP54/IP65
Medium Temperature Range -10℃ ~ 50℃ (compact type)
Ambient Temperature Range -10℃ ~ 50℃
Ambient Humidity Range 0-95% relative humidity, non-condensing
Housing Material Aluminum alloy
Installation Method Compact unit design, upper and lower brackets and measuring unit tightened by screws