Ultrasonic Level Meter
Product categories
Ultrasonic Level Meter
GENERAL INFORMATION
Ultrasonic level meters provide reliable, non-contact continuous level monitoring by utilizing the time-of-flight principle. By emitting ultrasonic pulses that reflect off the liquid surface, the device calculates distance based on the round-trip travel time. Since the sensor never touches the process medium, it is an ideal solution for measuring aggressive, corrosive, or viscous fluids, making it widely effective in water and wastewater treatment, chemical storage, and food processing applications.
BRIEF INTRODUCTION
Ultrasonic level meters provide reliable, non-contact continuous level monitoring by utilizing the time-of-flight principle. By emitting ultrasonic pulses that reflect off the liquid surface, the device calculates distance based on the round-trip travel time. Since the sensor never touches the process medium, it is an ideal solution for measuring aggressive, corrosive, or viscous fluids, making it widely effective in water and wastewater treatment, chemical storage, and food processing applications.
The working principle of the ultrasonic level meter is that the ultrasonic pulse emitted by the transducer (probe) is reflected after contacting the surface of the measured medium, and part of the echo reflected is received by the transducer and converted into an electrical signal.
The ultrasonic pulse propagates at the speed of sound waves, and the time from emission to reception is in direct proportion to the distance between the transducer to the medium surface. The relation between the distance D, the sound speed C and the time T can be expressed by the following formula:
S=C×T/2
ADVANTAGES
- Adopting the advanced microprocessors;
- Unique echo processing technology;
- False echo storage function;
- Built-in temperature compensation;
- Small beam;
- Simple scaling and calibration;
MAIN SPECIFICATIONS
| PWCS71H
|
Features: Simple installation and debugging, low power consumption. It can be used for serial port and commissioning PC, Chinese and English menu, with echo curve display function, economical. Application: Agricultural irrigation, sewage treatment, hydrology and water conservancy. Measuring range: Standard probe: (0.25~5)m Anti-corrosive sealed probe: (0.25~4)m Process connection: G1½″A thread/ Flange/ Support Transducer enclosure material: PA66+GF30 or PVDF Process temperature: ( -40~70 )℃ Process pressure: Normal Accuracy: ±0.25% (full range) Signal output: RS485/Modbus protocol ( 6~24V DC) Explosion-proof rating:Exia IIB T6 Ga Protection rating: Plastic enclosure Ip66, Aluminum enclosure IP67 |
| PWCS72H
|
Features: Simple installation and debugging, low power consumption. It can be used for serial port and commissioning PC, Chinese and English menu, with echo curve display function, economical. Application: Agricultural irrigation, sewage treatment, hydrology and water conservancy. Measuring range: Standard probe: (0.3~10)m Anti-corrosive sealed probe: (0.3~8)m Process connection: G2″A thread/ Flange/ Support Transducer enclosure material: PA66+GF30 or PVDF Process temperature: ( -40~70 )℃ Process pressure: Normal Accuracy: ±0.25% (full range) Signal output: RS485/Modbus protocol ( 6~24V DC) Explosion-proof rating:Exia IIB T6 Ga Protection rating: Plastic enclosure Ip66, Aluminum enclosure IP67 |
| PWCS73H
|
Features: Simple installation and debugging, low power consumption. It can be used for serial port and commissioning PC, Chinese and English menu, with echo curve display function, economical. Application: Agricultural irrigation, sewage treatment, hydrology and water conservancy. Measuring range: Standard probe: (0.4~15)m Anti-corrosive sealed probe: (0.4~10)m Process connection: M66*2 thread/ Flange/ Support Transducer enclosure material: PA66+GF30 or PVDF Process temperature: ( -40~70 )℃ Process pressure: (-0.02~0.1)MPa Accuracy: ±0.25% (full range) Signal output: RS485/Modbus protocol ( 6~24V DC) Explosion-proof rating:Exia IIB T6 Ga Protection rating: Plastic enclosure Ip66, Aluminum enclosure Ip67 |
| PWCS74H
|
Features: Simple installation and debugging, low power consumption. It can be used for serial port and commissioning PC, Chinese and English menu, with echo curve display function, economical. Application: Agricultural irrigation, sewage treatment, hydrology and water conservancy. Measuring range: Standard probe: (0.5~20)m Anti-corrosive sealed probe: (0.5~15)m Process connection: M95*2 thread/ Flange/ Support Transducer enclosure material: PA66+GF30 or PVDF Process temperature: ( -40~70 )℃ Process pressure: Normal Accuracy: ±0.25% (full range) Signal output: RS485/Modbus protocol ( 6~24V DC) Explosion-proof rating:Exia IIB T6 Ga Protection rating: Plastic enclosure Ip66, Aluminum enclosure Ip67 |
MAIN SPECIFICATIONS
| Product model | PWCS71H
|
PWCS72H
|
PWCS73H
|
PWCS74H
|
| Process connection | Thread G1½” A | Thread G2” A | Thread M66*2 | Thread M95*2 |
| Flange/Support | Flange/Support | Flange/Support | Flange/Support | |
| Transducer material | PA66+GF30/PVDF | PA66+GF30/PVDF | PA66+GF30/PVDF | PA66+GF30/PVDF |
| Transducer seal | Fluorelastomer | Fluorelastomer | Fluorelastomer | Fluorelastomer |
| Weight (depending on process fitting) |
1.3KG | 1.4KG | 1.5KG | 1.9KG |
| Voltage supply | |
| Standard model | 6~26V |
| Power consumption | Max. 12mA(12V) |
| Ripple allowed | -<100Hz USS<1V -(100~100k)Hz USS<10mV |
| Cable parameters | |
| Cable inlet / plug | one cable inlet M20×1.5 (cable diameter: 5~9mm) one plug M20×1.5 |
| Wiring terminal of spring | Cross-section of conductor 2.5mm² |
| Output parameters | |
| Output signal | RS485 Modbus RTU |
| Damping time | 0~30s adjustable |
| Housing | |
| Casing material | Aluminum |
| Casing sealing | Fluoroelastomer |
| Display on the upper lid | PC |
| Grounding end | Stainless steel |
| Product model | PWCS71H | PWCS72H | PWCS73H | PWCS74H |
| Near blanking area | 0.35m | 0.3m | 0.4m | 0.5m |
| Max. measuring standard probe | 5m | 10m | 15m | 20m |
| Min. measuring standard probe | 4m | 8m | 10m | 15m |
| Ultrasonic frequency | 52kHz | 50kHz | 40kHz | 28kHz |
| Launching angle | 5° | 3° | ||
| Measurement interval | > 2 second (Depending on parameter setting) | |||
| Adjustment time | > 3 second (Depending on parameter setting) | |||
| Display resolution | 2mm | |||
| Repeatability | ±1mm | |||
| Compressibility factor | <0.05% (full range) | |||
| Process temperature | (-40~70) °C | |||
| Relative humidity | <98% | |||
| Pressure | <0.1MPa | |||
| Vibration tolerance | Mechanical vibration 1m/s2 | |||
PRODUCT PHOTOS